MotionSuite™ Series Machine Controller Programming Manual Chapter 3: Advanced Programming Methods
3-13
An example of the input/output register delivery is shown as follows:
! User Function Creation
The steps for creating a user function are described with the example shown below.
To create a user function, follow the steps below:
a. In the File Manager screen, open [Programs
Function Programs], right-click
Specifications
Designate servo axis number and speed data,
then set them up in the parameter [Fast feed
speed OLxx22].
Motion program
MW00030 = Servo axis number (1 or 2)
ML00032 = Fast feed speed
UFL FUNC-T1 MW00030 ML00032, DB000001;
X Register
Y Register
XW00000
XW00001
XW00002
XW00016
MA00100
Motion program description
UFC TESTFUNC DB00000 DB000001 MW00030 MW00032 MA00100, DB0000002 MW00040
YW00000
YW00001
YW00002
YW00015
AW00000
AW00001
AW00002
MW00000
MW00001
MW00002
MW00032
DB000001
DB000002
MW00040
DB000000
MW00032
Figure 3.8: Motion Program Description