3 Commands for Preparation Process
3.2.17 Set Coordinate System (POS_SET: 20H)
3-30
3.2.17 Set Coordinate System (POS_SET: 20H)
Send a POS_SET command to set the position coordinate system.
(1) POS_SET Command (20H)
The specifications of the POS_SET command are described below.
(2) PS_SUBCMD Specifications
The specifications of PS_SUBCMD are described below.
REFE (Reference Point Setting)
0: Does not set reference point.
1: Sets reference point. The coordinates will be determined and the zero point position (ZPOINT) and soft-
ware limit setting will be enabled.
POS_SEL (Coordinate system selection)
3: Sets APOS (feedback position in machine coordinate system), and sets the positions of all coordinate sys-
tems (TPOS, IPOS, POS, MPOS, APOS) to POS_DATA.
Byte
POS_SET
Description
Command Response
1 20H 20H
Phases in
which the
command can
be executed
Phase 2 and 3
Synchronization
classification
Asynchronous
command
2ALARM
Processing
time
Within commu-
nications cycle
Subcommand Cannot be used
3
STATUS
Sets the current position to the position specified by POS_DATA.
The origin (ZPOINT) and software limit settings are enabled by setting a
reference point.
•See (2) PS_SUBCMD Specifications for details on PS_SUBCMD.
Specify the position (coordinates) in POS_DATA.
A warning will occur and the command will be ignored in the following
cases.
- A number out of the range is set in PS_SUBCMD: Data setting warn-
ing 2 (A.94B)
4
5 PS_SUBCMD PS_SUBCMD
6
POS_DATA POS_DATA
7
8
9
10
11
12
13
14
15
16 WDT RWDT
D7 D6 D5 D4 D3 D2 D1 D0
REFE 0 0 0 POS_SEL
Zobrazit stránku 60