3 Commands for Preparation Process
3.2.10 Turn Servo ON (SV_ON: 31H)
3-20
3.2.10 Turn Servo ON (SV_ON: 31H)
Send the SV_ON command to power the servomotor and make it ready for operation.
(1) SV_ON Command (31H)
The specifications of the SV_ON command are described below.
The HWBB function cannot be used with DC power input Σ-V series SERVOPACKs (SGDV-E11).
Byte
SV_ON
Description
Command Response
1 31H 31H
Phases in
which the
command can
be executed
Phase 2 and 3
Synchronization
classification
Asynchronous
command
2ALARM
Processing
time
Normally 50 ms
(10 s max.)
Subcommand Can be used
3
OPTION STATUS
Powers the servomotor and makes it ready for operation.
Command warning 1 (A.95A) will occur and the command will be
ignored if the command is sent:
- During alarm occurrence (When ALM of STATUS is 1)
- When the main power supply is OFF (PON of STATUS is 0)
- When the HWBB signal is ON (HWBB of IO_MON is 1)
*
- Before completion of execution of SENS_ON when an absolute
encoder is used
OPTION field can be selected
Upon completion of execution of this command, the reference position
(POS) must be read, and the controller coordinate system must be set up.
4
5
MONITOR1
6
7
8
9
MONITOR2
10
11
12
13 SEL_MON1/2 SEL_MON1/2
14
IO_MON
15
16 WDT RWDT
17
Subcommand
area
Subcommand
area
18
19
20
21
22
23
24
25
26
27
28
29