3 Commands for Preparation Process
3.2.5 Check Device ID (ID_RD: 03H)
3-12
When the DC Power Input Σ-V Series SERVOPACKs (SGDV-E11) are Used
• SERVOPACK Model
*1: Model code, *2: Current capacity, *3: Power supply voltage specifications, *4: Interface specifications,
*5: Design revision order, *6: Options
Example: ID_RD when DC power input Σ-V series SERVOPACK (SGDV-2R9E11A) is used.
• Servomotor Model
*7: Model code, *8: Rated output, *9: Power supply voltage, *10: Encoder type, *11: Design revision order,
*12: Shaft-end specifications, *13: Options
• Software version is binary data.
• Model is expressed in ASCII code and “00 (NULL)” is added at the end of each character string.
• 50H and 52H of DEVICE_CODE are reserved for system.
• When the Safety Option unit or/and Feedback Option unit are not connected, 0 is set to all the ID data.
• For an external encoder, the ID of the encoder connected to the Feedback Option unit is set.
(Therefore, 0 is set to all the ID data when no Feedback Option unit is connected.)
• When an encoder option for fully-closed loop control is connected to the Feedback Option unit, 0 is set to all
the ID data of Feedback Option unit.
Device Type/Name
DEVICE_
CODE
OFFSET
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0
D
0E 0F 10 11 12
SERVOPACK
Model 00H a S G D
∗
1
∗
2
∗
2
∗
2
∗
3
∗
4
∗
4
∗
5
∗
6
∗
6
∗
6
∗
6
∗
6
∗
6
00
Software
version
02H Ver.
Servomotor
Model 20H S G M
∗
7
∗
7
–
∗
8
∗
8
∗
9
∗
10
∗
11
∗
12
∗
13
00
Encoder
software
version
12H Ver.
External
Encoder
Model 30H
Software
version
32H Ver.
Safety Option
Unit
Model 60H
Software
version
62H Ver.
Feedback
Option Unit
Model 70H
Software
version
72H Ver.
OFFSET 00 01 02 03 04 05 06 07 08 09 0A 0B 0C