No. Name
User
Setting
d3-01 Jump Frequency 1
d3-02 Jump Frequency 2
d3-03 Jump Frequency 3
d3-04 Jump Frequency Width
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Maximum Output Frequency
E1-05 Maximum Voltage
E2-01 Motor Rated Current
E2-03 Motor No-Load Current
H1-03
Multi-Function Digital Input Terminal S3 Function
Selection
H1-04
Multi-Function Digital Input Terminal S4 Function
Selection
H1-05
Multi-Function Digital Input Terminal S5 Function
Selection
H1-06
Multi-Function Digital Input Terminal S6 Function
Selection
H1-07
Multi-Function Digital Input Terminal S7 Function
Selection
H2-01 Multi-Function Contact Output (Terminal M1-M2)
H2-02
Multi-Function Contact Output 2 (Terminal M3-
M4)
H2-03
Multi-Function Contact Output 3 (Terminal M5-
M6)
H3-01 Terminal A1 Signal Level Selection
H3-02 Terminal A1 Function Selection
H3-03
Terminal A1 Gain Setting
H3-04
Terminal A1 Bias Setting
H3-09 Terminal A2 Signal Level Selection
H3-10 Terminal A2 Function Selection
H3-11
Terminal A2 Gain Setting
H3-12
Terminal A2 Bias Setting
H3-13 Analog Input Filter Time Constant
H3-14 Analog Input Terminal Enable Selection
H3-16 Terminal A1 Offset
H3-17 Terminal A2 Offset
H4-01
Multi-Function Analog Output Terminal FM
Monitor Selection
H4-02
Multi-Function Analog Output Terminal FM Gain
H4-03
Multi-Function Analog Output Terminal FM Bias
H4-04
Multi-Function Analog Output Terminal AM
Monitor Selection
L1-01 Motor Overload Protection Selection
L1-02 Motor Overload Protection Time
L2-01 Momentary Power Loss Operation Selection
No. Name
User
Setting
L2-03 Momentary Power Loss Minimum Baseblock Time
L2-05 Undervoltage Detection Level (Uv1)
L3-02 Stall Prevention Level during Acceleration
L3-03 Stall Prevention Limit during Acceleration
L3-04 Stall Prevention Selection during Deceleration
L3-06 Stall Prevention Level during Run
L3-11 Overvoltage Suppression Function Selection
L3-25 Load Inertia Ratio
L5-01 Number of Auto Restart Attempts
L5-02 Auto Restart Fault Output Operation Selection
L5-03 Time to Continue Making Fault Restarts
L5-04 Fault Reset Interval Time
L5-05 Fault Reset Operation Selection
L6-01 Torque Detection Selection 1
L6-02 Torque Detection Level 1
L6-03 Torque Detection Time 1
L6-13 Motor Underload Protection Selection
L6-14
Motor Underload Protection Level at Minimum
Frequency
L8-02 Overheat Alarm Level
L8-05 Input Phase Loss Protection Selection
L8-06 Input Phase Loss Detection Level
L8-07 Output Phase Loss Protection
L8-09 Output Ground Fault Detection Selection
L8-38 Carrier Frequency Reduction Selection
n1-01 Hunting Prevention Selection
n1-02 Hunting Prevention Gain Setting
n3-04 High-Slip Braking Overload Time
n3-13 Overexcitation Deceleration Gain
o1-03 Digital Operator Display Selection
o1-09 Frequency Reference Display Units
o1-10 User-Set Display Units Maximum Value
o1-11 User-Set Display Units Decimal Display
o2-04 Drive Model Selection
o4-03 Cooling Fan Maintenance Operation Time Setting
o4-11 UB-9 to UB-16 Initialization
S1-01 Stillness Control Selection
S1-02 Voltage Reduction Rate
S1-03 Voltage Restoration Level
S1-04 Voltage Restoration Complete Level
S1-05 Voltage Restoration Sensitivity Time Constant
S1-06 Voltage Restoration Time Constant at Impact
S2-01
Sequence Timer 1 Start Time
S2-02
Sequence Timer 1 Stop Time
S2-03
Sequence Timer 1 Day Selection
S2-04 Sequence Timer 1 Selection
S2-05 Sequence Timer 1 Reference Source
H.3 User Setting Table