60 VS-616G5 Programming Manual
Section E: Motor Parameters
E2 Motor 1 Set-up
Sets the motor leakage inductance in units of 0.1%. The default setting varies depending on the
inverter model setting (O2-04).
Setting Range: 0.00 to 1.00
Factory Default: 0.5
Sets the motor iron core saturation coefficient at 50% of the magnetic flux. This parameter is set auto-
matically during auto-tuning, so it does not need to be changed.
Setting Range: 0.00 to 1.00
Factory Default: 0.75
Sets the motor iron core saturation coefficient at 75% of the magnetic flux. This parameter is set auto-
matically during auto-tuning, so it does not need to be changed.
Setting Range: 0.0 to 10.0%
Factory Default: 0.0%
Sets the motor mechanical loss as a percentage of motor rated output power, in units of 0.1%.
Setting Range: 0 to 65535
Factory Default: 14 (Factory default depends on inverter capacity.)
This parameter sets the motor iron loss of the torque compensation.
E2-06 Leakage Inductance Leak Inductance
A A
E2-07 Core-Saturation Compensation Coefficient 1 Saturation Comp1
A A
E2-08 Core-Saturation Compensation Coefficient 2 Saturation Comp2
A A
E2-09 Motor Mechanical Loss Mechanical Loss
A
E2-10 Motor Iron Loss Torque Compensation <1110> Tcomp Iron Loss
A A