5.5 Precaution on Using MP2300S
5.5.1 Precautions when User Definition File is Configured/Changed
5-53
Outline of Motion Control Systems
5.5 Precaution on Using MP2300S
This section explains precautions when a user definition file is configured/changed and when setting a scan time.
5.5.1 Precautions when User Definition File is Configured/Changed
System settings, scan time settings, and module configuration definitions must be saved in flash memory (flash save).
When a system setting, scan time setting, or module configuration definition is configured/changed, be sure to use
MPE720 to flash save it. Note that when the MP2300S power supply is turn ON again without flash saving, the config-
ured/changed data may be lost.
• System Setting
• Scan Time Setting