Yaskawa MP2300S Basic Module Uživatelský manuál Strana 136

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 460
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 135
5.1 Startup Sequence and Basic Operation
5.1.2 Startup Sequence
5-3
Outline of Motion Control Systems
5.1.2 Startup Sequence
The startup sequence for the MP2300S from the moment when the power has been turned ON is shown in the follow-
ing flowchart.
Note: Refer to 5.1.3 Startup Sequence Operation Details on the next page for details on (1) to (5).
FLASH
ON
OFF
DWG.L
executed
Output
Output
DWG.H
executed
Completed
after one cycle.
DWG.I
executed
Input
Input
Low-speed
scan
High-speed
scan
Interrupt
signal
Ladder program
Power ON
Startup
self-diagnostics (1)
Memory clear
FLASH
RAM
Copy
Watchdog timer
start
DWG.A executed
(Ladder program)
Order of priority
High Low
Online self-diagnostics
(5)
Background
Normal operation
Self-configuration
execution (2)
Configuration mode
RUN indicator lit
User program stops
Operation starts (3)
Operation stops (4)
RDY indicator lit
Judges the setting
of switch 3 (CNFG)
of DIP switch SW1
Judges the
setting of switch 6 (STOP)
of DIP switch SW1
Judges the
setting of switch 4 (INIT)
of DIP switch SW1
Zobrazit stránku 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 459 460

Komentáře k této Příručce

Žádné komentáře